25 Using Controlled Acoustics to Find a Stuck Pig

Abstract

SCOPE:

A pipeline operator was preparing to run an in-line inspection on a 4’’ NGL Line in South Texas.   Prior to the inspection, the operator launched a 31’’ Mandrel Pig with a Gauge Plate and Cleaning Tool.  The mandrel pig was unable to flow the total distance and got caught somewhere in the middle of the pipeline.  An unsuccessful second and third pig was launched two weeks later to try and dislodge the first gauge plate pig.   Several methods were used to locate the pigs, including geophones, transmitter detection receivers, and mainline block valve pressure differentials.

PROCESS:

To find the missing pig, Seismos used an Acoustic Transmitter, Acoustic Sensor, and Data Acquisition Unit (DAQ) to create controlled acoustics within the pipeline.  The equipment was attached to the pipeline at above-ground stations through standard Male Pipe Thread (MPT) connections.

The acoustic transmitter emits a pressure pulse that causes a tube wave to travel via the pipeline media down the length of the pipe. The acoustic energy reflects off the object and the return signal is captured by the acoustic sensor. Signal processing software is used to analyze the return signal providing the object’s precise location.

RESULTS:

Seismos informed the operator of the location of the lost pigs, which ended up being 2+ miles away from where the operator initially thought going into the project. The operator decided to start excavating based on Seismos’ analysis.   The pigs were found precisely where Seismos’ analysis had indicated.

********