Stress corrosion cracks are typically found in colonies comprised of multiple parallel aligned cracks. However, they are usually assessed as individual (or single interlinked) cracks, assuming the deepest of the colony represents the crack driving force for failure. This common approach does not account for the effects of crack shielding. It is known that neighboring cracks may dissipate stress intensity and result in a lower crack driving force.

In this work we use FEA to estimate the stress intensity factors associated with crack colonies. Results demonstrate how stress intensities in colonies are decreased relative to those of individual cracks. This is consistent with recent industry model studies that tend to underestimate critical failure pressures of in-service SCC flaws. It also indicates a fracture mechanics contribution to the known phenomenon of crack dormancy, which is often attributed to electrochemical and kinetic factors. The findings can be used to modify fitness for service assessments and improve SCC integrity program efficiency.