179

Previously, rule of thumb suggested that leaks only occur below 30% SMYS. Unfortunately, there have always been outliers below 30%. Catastrophic rupture conservatism was therefore assumed, and a high corresponding thermal radiation dosage in the PIR was estimated for static and non-static receptors. However, many breaches occur as leaks with a much reduced risk. This new methodology provides a reliable method to determine if the breach is a leak or rupture.  

 This Basic Rupture Framework (BR) methodology collapses a detailed seven-dimensional engineering analysis of more than ٣x١٠5 combinations into a simple two-dimensional plot. The BR methodology requires the operating pressure (default = MAOP) and an estimated a failure pressure (default = SMYS) to determine if the failure will be a leak or rupture. If a leak, then the BR consequence methodology will estimate a smaller, more realistic PIR and provide a better estimate of the actual consequences. This paper summarizes our PHMSA engineering report, describing how the BR Framework was developed and used to evaluate and plot >300,000 combinations of actual pipe attributes and operating conditions over decades of pipe to simplify the leak or rupture outcome.  

Read/Download PaperGradeAvailable after the event