1Enbridge, Houston, USA. 2Stress Engineering, Houston, USA
This is based on a study that was performed by Enbridge in conjunction with Stress Engineering to compare the 3 most widely used in-situ material property verification tools based on realistic conditions on vintage pipe. There is plenty of historical work presented by the manufacturers of the equipment (MMT, Frontics, Plastometrex) however all of this was performed by experts in the field who also design the equipment.
The objective of the study was to produce realistic results by using trained NDE technicians to operate the equipment with the manufacturers only being allowed to provide non-contact support simulating what they could feasibly do during an excavation where they are not onsite. The results of the testing clearly show that it makes a difference, not necessarily in the tool material property results, but the compliance and test location selection.
The methodology applied was to treat this as if each of the 18 samples was a separate site. Have the NDE technician armed with their procedures and the information that we wanted a 49CFR192.607 compliant inspection. They were given all the time needed to perform the work and produce their reports with minimal interaction between the crews. Samples for destructive testing were sourced from the same locations as the in-situ methods to provide a direct test of their results.
The results of the testing showed that with the instructions given the technicians were able to perform the work, however a non-compliance issue occurred because the technicians had a question about the locations and instead of asking the Client/Operator they asked their manager and he gave a non-code compliant answer. The inspection should be in 2 quadrants however he instructed them to just do 2 locations site by side. There is also one joint where the seam was incorrectly identified by 2 of the technicians so their data for the seam location is not accurate as they were 180 degrees off the seam. The overall results of the in-situ testing vs the destructive testing supports the claims by the manufacturers and is in line with the data they provide, but the errors highlighted additional training needs for both NDE vendors and operators.
The implications based on the results are that although the tools are accurate and can give quality data, the human factors need to be controlled in order to maintain compliance.
Available after the event