240

Adnan Chughtai1, Rodolfo Santos1, Joshua May1, Casey Lajaunie2, Gary Winfrey2, Fabio Chiappa3, Ana Paula Gomes3, Marco Marino3, Gerardo Califano3, Valeria Vandone3, Massimiliano Biagini3, Ilenia Romagnoli3, USA.2, USA.3

1SLB, Houston, USA. 2Enbridge, Houston, USA. 3Enivibes, Milan, Italy

Pipeline inspection gauges (Pigs) are vital tools in maintaining and monitoring pipeline health by clearing material and fluid buildup within a line or in the case of in-line inspection (ILI) tools, offering insight on the condition of the pipeline. Manual pig tracking can be time and resource consuming as well as increased risk of injury to personnel due to pipeline right of way (ROW) and public road exposure. A means of accurately monitoring pig location and velocity in real time has the potential to save operational costs, reduce pipeline downtime, and eliminate costly reruns of tools that require consistent run velocities.

In this study, vibroacoustic technology (VT) was applied in a non-invasive and easily retrofittable layout, through the installation of vibroacoustic sensor blocks – comprising a pressure gauge, hydrophone, and accelerometer -  at valve stations on PETR-TVIO 16, a 61.5-mile long, 30-in natural gas pipeline section, to monitor a cleaning pig  campaign culminating in an IL I tool run. Leak tests were also run by throttling product from the pipeline through designed orifices to the atmosphere to simulate various diameter leaks between monitoring sensor blocks.

During the cleaning run manual tracking was unable to follow the cleaning pigs through the entire run as a result of accessibility issues, leading to uncertainty regarding the pig’s location for 40 miles of the run; VT, on the other hand, was able to continuously track the pig through the run, providing tracking and the velocity of the pig every 2 minutes. While the ILI tool did measure location and velocity during the run, these data were available only after the run was completed and could not assist in the operation. The data collected by the ILI tool confirmed the tracking capability of the vibroacoustic sensor blocks. (NB: the ILI tool was tracked manually and the data correlated well with the VT tracking). Leak tests performed following a calibration phase detected simulated leaks using 1-, 0.5-, 0.37-, and 0.25-in-diameter orifices, with a 19.4-mile separation between the two nearest sensor blocks.

The study successfully monitored a pigging campaign and detected simulated leaks, demonstrating that VT presents a multifaceted value proposition for pipeline integrity and monitoring operations.

Read/Download PaperGradeAvailable after the event