84 Axial Flaw and Crack Detection in Multi-diameter Low-Pressure Gas Pipelines

Abstract

Louisville Gas and Electric (LG&E) owns and operates numerous natural gas transmission pipelines in the greater Louisville, KY area. Many were constructed during the 1950’s and therefore present extensive challenges to inline-inspection (ILI) efforts. Multi-diameter pipeline geometry and transient operating conditions combine to create an environment that proves difficult for running in-line inspection tools. LG&E has utilized high resolution geometry and metal loss detection solutions optimized for low-pressure multi-diameter pipelines ILI devices in their integrity management program. There was a desire to expand the technologies deployed to include technologies best capable of detecting axially oriented anomalies and cracking.  To address these concerns, circumferentially induced magnetic flux leakage (MFL-C) and electromagnetic acoustic transducer (EMAT) technologies were suggested, however applying these detection methods in low-pressure multi-diameter pipelines was not available.

 

MFL-C & EMAT-C ILI devices capable of inspecting a pipeline with both 16″ and 20″ diameters in a low-pressure gaseous environment needed to be developed. In addition, traversal of all restrictive features, such as tight radius bends and minimal spacing between fittings, must be achieved with minimal differential pressure to facilitate stable run behavior and allow optimal data capture. ROSEN reviewed all known details regarding the targeted pipelines and compiled a list of challenging fittings to define the required mechanical passage capabilities. The conceptual design, manufacturing, and assembly stages of development resulted with redesigned low-friction ILI tools capable of full circumferential sensor coverage in 16″ - 20″ pipeline diameters. The tools were then pumped with water through a test loop that included the most restrictive features identified in the targeted pipelines. Performance results confirmed mechanical passage and determined the average ∆P’s necessary to pass the included restrictive features. Finally, validation pull tests occurred to confirm data capture functionality within established specifications. After mechanical and data capture performance were verified, the new low pressure multi-diameter 16/20″ MFL-C & EMAT-C were deemed fit for service and deployment.

 

This technical paper outlines the development process with examples and observations from the testing program. Difficulties related to MFL-C & EMAT-C technologies as related to low-pressure and multi-diameter environments are discussed in further detail. The paper includes real-world operational challenges and inspection results from two successfully inspected pipelines, as well as a discussion of iterative ILI tool improvements.

Read/Download PaperGradeAvailable after the event