Abstract
The presence of low frequency (LF) ERW seam weld defects (e.g., lack of fusion, stitching, and hook cracks) can reduce the pressure-carrying capacity of a line pipe. In cases where these defects may have been subjected to a hydrostatic test, there is a possibility that the seam weld defects could fail at a lower pressure upon re-pressurization. This type of failure, which occurs at a pressure less than the previous pressure and where no time dependent degradation has contributed, is commonly referred to as a pressure reversal.
LF ERW seam flaws can fail when held at a constant load below the straight-off to failure load. This is because ductile materials can exhibit time-dependent creep behavior even at room temperature. Evidence of time dependent behavior is provided by failures that occur during the maximum pressure hold period of a hydrostatic test.
Time dependent growth and reverse yielding can be detrimental when performing multiple high pressure hydrostatic tests which can result in many blowouts during the hydrotests, and flaws that survive the hydrotest may experience some ductile tearing that could be detrimental to fatigue life.
This paper covers:
- A testing methodology that can measure the time dependent creep behavior of vintage LF ERW bondline flaws from actual small-scale test samples, at elevated stress levels as well as stress reversals (creep and pressure reversals). The testing would be analogous to pressure testing.
- A series of tests used to measure the growth of actual bondline flaws of vintage LF ERW seams at elevated stress levels.
- Implications on managing pressure reversals in hydrostatic tests.
The testing methodology is successful in showing the time-dependent creep behavior of the bondline flaws at elevated loads, as well as establishing that after reducing the pressure down to zero and back to load, the time dependent creep behavior could be re-activated.
Available after the event