152

Scott Riccardella1, Peter Veloo2, Roger Royer3, Jeff Milligan3, USA.2, USA.3

1Structural Integrity Associates, Denver, USA. 2Pacific Gas and Electric Company, San Ramon, USA. 3Structural Integrity Associates, State College, USA

An engineering critical assessment (ECA) is a regulatory accepted method for reconfirming the maximum allowable operating pressure (MAOP) of pipelines.  The ECA process involves evaluating:

  • Relevant material properties,
  • Operational history and environment,
  • Prior assessments,
  • In-service degradation,
  • Possible failure mechanisms, and
  • Defect characteristics (prior, current and future).

These factors are analyzed for the loadings and operating conditions relevant to potential threats with additional assessments performed to mitigate the risk from these threats.  This process was successfully applied and found beneficial in evaluating facility and station piping throughout the PG&E system. Unique threats were identified with lap welded pipelines requiring specialized Non-Destructive Examination (NDE) processes and a fracture mechanics evaluation for identified defects. The paper will discuss the PG&E ECA process, specialized NDE methods, and specialized evaluation for lap welded defects that was applied.

Read/Download PaperGradeAvailable after the event