135

James Barlow1, Mukund Belavadi2, Simon Crompton2, William Deschamps-Robertson1, McKenzie Kissel1,  Mark Ryan2

1Onstream Pipeline Inspection, Calgary, Canada, 2Phillips 66, Houston, USA

In todays economic environment, Operators are reluctant to reduce the throughput in their pipelines. This can be at odds with the Inspection technology ideal performance window. With this in mind, adaptive speed control systems were developed in the mid 1990's to allow the MFL tool to operate at its ideal velocity in gas transmission bullet lines (~2000 psig at 10 m/s). This paper outlines the development of an adaptive speed control system that is capable of operating at both extremes of pressure. This system has proven itself at high pressure high flow gas lines and more recently on low pressure high flow lines an area traditionally ignored by ILI vendors for these systems.

A case study will be shared showing how operators with gas gathering systems consisting of low-pressure lines and tight fittings, that generally result in poor ILI tool dynamics, can be overcome with the use of a speed control system. This allows high quality integrity decisions to be made without restricting product throughput.

Read/Download PaperGradeAvailable after the event