Abstract

In the late 1990’s, the discovery of stress corrosion cracking (SCC) in orientations other than the axis of the pipe triggered new studies into the factors associated with off-axial cracking. Since most of the crack colonies appeared to be close to 90 degrees to the axis of the pipe, the investigations focused on circumferentially oriented SCC (CSCC). Notwithstanding, there have been many documented cases of cracks at angles other than 90 degrees, notably at the same angle of the spirally applied tape in tape-coated pipelines. These off-axis cracks have been incorporated into the models developed to address CSCC.

CSCC management programs use of a combination of quantitative and qualitative data involving bend strain along with susceptibility criteria, geohazards and areas of pipe movement, and ILI where available. As CSCC investigative and remedial work continues, off-axis cracking is starting to be found in larger numbers, with skew angles to the axis of the pipe ranging from 45 to 90 degrees. These skew angles can exceed the specified detection range of ILI tools, leaving operators without a diagnostic option for modelling these types of features.

This study illustrates the successful management of both circumferential and off-axis SCC by using a magnetic based ILI system to determine crack depth, crack length and the primary crack colony skew angle. The determination of all these crack attributes, particularly the skew angle, enabled modelling the interaction between axial and hoop stresses, to calculate the pipeline’s remaining strength.

The diagnostic data for the program was obtained using ILI technology that included three sensor systems: AMFL, CMFL, and IDD-SM™. This technology reliably provided crack length and depth sizing with an accuracy of +/- 15% and, for this study, the measurements of the primary colony skew angle with a target accuracy +/- 10°.

The ILI’s crack sizing and crack skew angle measurements were corroborated through an extensive excavation campaign, which also established ILI detection (POD) and identification (POI) greater than 95%, this accuracy supported the use of crack model predictions that could be incorporated into reliability programs.

The ILI reported and verified CSCC locations also supported the management of geohazards as it was possible to identify potential ground movement locations that were not highlighted by geotechnical desktop and field investigations.

The lines used in this study had a nominal diameter of 8.625” and were investigated for occurrences of all threat types including off-axis and circumferential cracking. Field inspection data was gathered to support the finding of this study and the implementation of the model.

Read/Download PaperGrade