Traditionally, Gulf of Mexico (GoM) Outer Continental Shelf (OCS) owners and operators have sought alternate methods to assess the integrity of their gathering lines than inline inspection. In April 2010, the Deepwater Horizon explosion, and subsequent blowout, brought significant scrutiny from both state and federal regulatory agencies.
A customer approached Intero Integrity Services in 2019, in order to evaluate feasibility of inline inspections of its liquid gathering system in the GoM. The feasibility included three areas: 1) Technical ability to inspect; 2) Cost of inspection; and 3) Value of reported results.
From a technical standpoint, the customer conditions challenged just about every aspect of standard inline inspections: Never pigged for maintenance nor integrity assessment; 1500 psi static pressure; limited operating space on platform; remote location (90+ miles offshore); inability to track during the inspection (2,000’ water depth); limited pipeline availability based on production schedule; 8” nominal x 0.812 wall thickness x 25 mile pipeline; back to back “jumpers” to loop pipeline; and pumped in sea water. This paper will explain how, working closely with the operator, flow conditions were tightly controlled.
From a cost perspective, the customer had limited assessment options. The field was initially developed in 1998 and has operated in multi-phase production for 20+ years. If pipeline replacement is required, the field will just shut-in based on ROI compared to the current production curve. External assessment methods are limited (ROVs and divers) and need to be more comprehensive. Other than inline inspection, a hydrotest was the only option. Again, not valuable information for the cost.
Corrosion was detected in an area that had limited access; therefore, the operator decided that an annual inspection would be conducted and detailed corrosion growth assessments completed, and also to quantify the effectiveness of corrosion mitigation methods. Data sets will be presented that show the challenges of detecting defects under external clamps, and the variability between said datasets.
With the 0.812” wall thickness, the only inline inspection solution was ultrasonic (UT) technology. Magnetic (MFL) tools would not be able to saturate the pipe wall to provide accurate measurements.