2024 – 45

Janille Maragh1, Jonathan Gibbs2, Peter Martin3, Jeffrey Kornuta4, Peter Veloo5

1Exponent, Inc., Menlo Park, CA, USA., 2Pacific Gas and Electric Company, San Ramon, CA, USA., 3RSI Pipeline Solutions, LLC, New Albany, OH, USA., 4Exponent, Inc., Houston, TX, USA., 5Pacific Gas and Electric Company, Oakland, CA, USA

1Exponent, Inc., Menlo Park, CA, USA. 2Pacific Gas and Electric Company, San Ramon, CA, USA. 3RSI Pipeline Solutions, LLC, New Albany, OH, USA. 4Exponent, Inc., Houston, TX, USA. 5Pacific Gas and Electric Company, Oakland, CA, USA

Abstract

Nondestructive testing (NDT) of chemical composition is a critical component of the Pacific Gas and Electric Company’s (PG&E) materials verification program. Additionally, 49 CFR § 192.607 states that the operator must “conservatively account for measurement inaccuracy and uncertainty using reliable engineering tests and analyses.” Accurate and precise NDT composition data can be used to determine or verify certain characteristics of a pipe, for example vintage, grade, or manufacturing process. However, it has been observed that composition measurements may at times be inconsistent across various field analytical tools, possibly due to the variability of experimental, environmental, and other statistical (random) factors. Anomalous field NDT measurements are problematic because they could lead to the mischaracterization of pipe features during the materials verification process.

In this paper, we present a tool for the in-field checking of chemical composition NDT data for potentially erroneous or inconsistent measurements. The presented tool, which is spreadsheet-based and therefore easily and independently implemented by operators, identifies sets of measurements that exhibit two commonly observed irregularities in field data: large standard deviations, which usually indicate the presence of outliers or excessive scatter; and greater-than-usual differences between the chemical compositions at different test locations on the same pipe joint. For a given set of measurements, the tool flags the standard deviation as too large if it is high relative to standard deviations that have been previously observed for the tool/element combination of interest. Large differences between the chemical composition measurements at different test locations on the pipe joint, which may be the result of surface contamination, surface preparation issues, or environmental differences, are identified through comparison to compositional differences that have been observed on all previously tested pipe joints. Because this tool is designed to work with raw data from NDT chemical composition tools, it may be used to enable field technicians to identify potential errors in near real-time. The improved data reliability increases confidence in downstream analysis and reduces the need to return to a site to perform re-work, allowing for a more efficient and less costly materials verification process. The implementation and in-field use of this tool for live retesting to mitigate potential downstream issues are demonstrated for a set of portable X-ray fluorescence (XRF) data.

Read/Download PaperGrade