In pipelines experiencing significant corrosion growth, frequent wall thickness measurements using In-Line Inspection (ILI) are beneficial. This paper defines ‘frequent inspections’ as those conducted less than a year apart. Increasing the frequency of these measurements allows for rapid assessment of mitigation measures’ effectiveness without the need for costly excavations. Ultrasonic ILI data enables evaluation on both a feature-specific and global scale. As corrosion rates decrease due to effective mitigation, inspection intervals can be extended. This paper explores three case studies at different stages of this approach.

The first case study addresses channeling corrosion, where frequent inspections were conducted until a reduction in corrosion growth rates was observed. The second case study examines pinhole corrosion, and the third case examines general corrosion. Both pipelines continue to be monitored frequently. Each case study is presented with statistical analysis of corrosion growth rates.

Additionally, operators rely on feature information spreadsheets as their primary view into the pipeline, which can be distorted by reporting practices. In the context of ultrasonic data, reporting only the deepest spot within a box may not adequately capture the extent of corrosion. This paper discusses reporting strategies for general and channeling corrosion to provide a more accurate representation.

KEYWORDS : ILI Analysis, ILI Applications, Corrosion Studies, Repair and/or Rehabilitation, Integrity Management Plans (IMP)