77 Leveraging Multiple ILIs and Technologies to Identify Possible Integrity Threats Under Type A Sleeves

Abstract

On August 14, 2020, a leak was discovered on Colonial Pipeline Company’s (Colonial) Line 1 pipeline in Huntersville, North Carolina. The release occurred at a dent, previously repaired with a Type A sleeve. Upon further investigation, it was found that external metal loss and a through-wall crack had developed in the dent sometime after the installation of the Type A sleeve. Type A sleeves are a common remediation method used to reinforce and repair certain anomalies on a pipeline. However, because the sleeve ends are not welded to the carrier pipe, Type A sleeves are not pressure-containing. A remediation plan to identify possible integrity threats under Type A sleeves and convert those Type A sleeves to pressure-containing Type B sleeves on Colonial’s mainlines was implemented.

In close conjunction, Colonial and Quest Integrity developed a plan to first identify every sleeve on Colonial’s mainlines. Once the comprehensive sleeve list was compiled, a qualitative analysis of all sleeve locations was initiated. Utilizing multiple inline inspections (ILI) and tool technologies, such as Ultrasonic Wall Measurement (UT-WM), Ultrasonic Crack Detection (UT-CD), and Combo (MFL + Caliper), each sleeve location was reviewed to determine:

  • The sleeve type (Type A or Type B).
  • Sleeve characteristics (Stacked/Segmented).
  • The anomaly type(s) observed under the sleeve.
  • The deepest reported metal loss depth (%) under the sleeve.
  • The presence of additional metal loss under the sleeve (unreported or reported).
  • If metal loss under the sleeve has preferential-to-the-sleeve characteristics.

Results from the sleeve review were used to provide a prioritization of the Type A to Type B conversions.

This paper uses case studies from this sleeve characterization and review project to show:

  • Given the right conditions, Type A sleeves may not inhibit external metal loss growth under the sleeve.
  • The importance of utilizing multiple ILI inspections and ILI technologies to identify integrity threats.
  • The methodology and decision tree to determine potential areas of preferential metal loss under sleeves.

Read/Download PaperGradeAvailable after the event