61 Know when using MFL for Effective Area is wrong!

Abstract

Performing corrosion assessments on reported MFL features is a fundamental competency in pipeline integrity management. ASME B31. G provides three methods of calculating burst pressure associated with defect assessment for corrosion, namely B31. G, Modified B31. G, and Effective Area. Each method is based on a geometry and depth profile of the corrosion defect, which may be explicit or an approximation. The technical documentation for each methodology’s application is widely available and well understood. However, the transformation of MFL signal data into metal loss feature characterization as a function of feature length, width, and depth for use in Effective Area calculations is not well understood. If the MFL based depth profile is not representative of the corrosion defect, then the burst calculation using the Effective Area methodology may not be conservative and potentially a safety concern. This paper will use a case study where MFL-A technology was incorrectly used to calculate burst pressure using the Effective Area methodology, highlight MFL technology’s challenge in providing accurate corrosion depth profiles to perform Effective Area calculations, and share guidance on how to qualify MFL data for use in Effective Area calculations.

Read/Download PaperGradeAvailable after the event