2024 – 83

Pablo Cazenave1, Sergio Limón1, Ravi Krishnamurthy1

1Blade Energy Partners, Houston, USA

Abstract

An onshore/offshore pipeline in South America transporting brine solution experienced a failure initially attributed to external circumferential cracking in an onshore section of the pipeline. The failed pipeline rested above ground in a concrete ditch exposed to ambient conditions. Field assessments and land surveys of the failed site indicated possible nearby land movement. This paper outlines the work conducted to review the Failure Analysis results, the aggregation of historic and recent in-line inspections (geometry + inertial + axial MFL), above-ground land movement survey data, and the identification of the cause of the circumferential cracking for the development of a short- and long-term remedial plan to address the effects on land movement on the integrity the pipeline.