2024 – 80

Nikolaos Salmatanis1, Amit Rajput2, Praveen Kumar2, John O'Brien3

1Chevron, Houston, USA., 2XaaS Labs, Sunnyvale, USA., 3itcSkilla, Houston, USA

Abstract

Reliable detection and accurate localization  (especially) of small leaks tends to be the weak link in Leak detection programs for oil & gas pipeline operators. The paper presents the results of a study aimed at assessing the feasibility of reliably identifying pipeline leaks using inline approaches based on minimally intrusive sensing devices  that are now available to pipeline operators.  These low form-factor sensing devices incorporate sensors based on Audio, Magnetometry, Pressure and Velocity.   A test pipeline flow loop was leveraged to create a customized test setup and a test execution methodology was developed and executed towards this end.  Sensing equipment from two different suppliers were used to collect various sensor datasets on separate test runs In test scenarios where leak signatures were identified, the team investigated the feasibility of ascertaining the limits of detection using such approaches. Key findings and Lessons learned are summarized

Read/Download PaperGrade