Magnetic Flux Leakage (MFL) inspection was the first technology introduced in the 1980’s to routinely inspect oil and gas pipelines for corrosion defects, and today it remains the most trusted In-line Inspection (ILI) technology for that purpose. Thousands of MFL inspections are carried out by ILI vendors each year ensuring pipeline operators can effectively manage their corrosion integrity programs. 

Since the introduction of high-resolution axial MFL inspection vehicles, there has been a substantial number of improvements in capabilities. These include inertial mapping units (IMU), speed control, increased sensor density and combination sensing (caliper, eddy current, transverse MFL and triaxial MFL measurement).

Even with these advances, surprisingly most MFL inspections only measure and use one of three components of magnetic flux field leakage that occur at a corrosion feature when magnetized by the inspection tool at a localised thinning of the pipe wall.  However, it is well proven that different corrosion morphologies will trigger significantly different leakage in these components. These characteristic signatures consequently provide an additional and robust means to identify corrosion profiles and interactions that in many cases are not detectable or distinguishable when using only a single axis – no matter how high the sensing resolution the inspection tool may have. Optimising sensor resolution in combination with measuring all three leakage components offers clear advantages, particularly when defect morphologies become challenging. 

This paper will provide a deeper insight as to how the three independent leakage components provide unique identifiers that can be used to accurately size pin holes, axial and circumferential slotting, and importantly de-construct complex morphologies and be used more effectively in the analysis process to improve POD, POI and POS. These identifiers not only ensure correct corrosion interpretation, but also that these defect types are identified correctly within the often hundreds of thousands of features within many miles of pipeline. 

The paper will conclude with a demonstration of how, in combination with monitoring of data accuracy for every validated inspection conducted, the adoption of data accuracy results as a key performance indicator can be effectively employed to target and drive continuous improvement of even the highest performing inspection technologies.