297

Due to its body-centered-cubic or BCC crystal structure, carbon steel exhibits a transition behavior of toughness along temperature.  The fracture is fully brittle with very low toughness at low temperature, known as lower shelf, and is fully ductile with saturated high toughness at high temperature, known as upper shelf.  For the transition region of temperature in between, the steel can exhibit mixed brittle and ductile fracture.  This transition behavior is well represented by the transition curve from a Charpy-V-Notch or CVN test.

In quasi static fracture mechanics-based tests, such as J-integral test or crack-tip-opening-displacement or CTOD test, the specimen can exhibit stable crack extension and early unstable crack extension, such as pop-in, if tested at multiple temperatures.  In s general transportation pipeline, the surface crack focused by integrity assessment is low constrained and initiates at a static status before failure.  Thus, its transition region is at a much lower temperature, more than 100 F for certain cases, than that of a dynamic CVN test or a quasi-static but high constrained standard J-Integral or CTOD test.  Thus, A crack feature in a pipe may fail at fully ductile model with burst pressure related to the toughness at upper shelf level even if the tests fall into the transition or even low shelf region at the operating temperature.

In this paper, equations are provided on how to calculate the temperature supporting fully ductile initiation of surface crack in a pipe based on tests data.  The worked examples are also provided to demonstrate the application.  Certain challenges and potential needs for extra tests are also discussed.