1Exponent, Menlo Park, CA, USA. 2Pacific Gas & Electric Company, Oakland, CA, USA. 3Applied Technology Services, San Ramon, CA, USA. 4RSI Pipeline Solutions, Columbus, OH, USA
Per 49 CFR § 192.607, operators may use nondestructive testing (NDT) in the materials verification of pipe joints without traceable, verifiable, and complete (TVC) records, provided that the methods are validated by comparison to destructive tests, account for measurement uncertainty, and are conducted by subject matter experts (SMEs) using properly calibrated equipment. As part of its materials verification program, the Pacific Gas & Electric Company (PG&E) collects NDT data on pipe joints. This includes both strength measurements in the form of instrumented indentation testing (IIT) data and chemical composition measurements, collected using X-ray fluorescence (XRF), laser-induced breakdown spectroscopy (LIBS), and laboratory analysis of filings samples. Following careful SME review of this NDT data, downstream analysis includes the use of this NDT materials characterization data in the probabilistic calculation of pipe grade.
This paper presents a case study that highlights the critical role of SME-led validation and cross-checking of NDT results in identifying discrepancies and improving material verification. This case study highlights the potential for inaccuracies even in certified lab results, emphasizing the importance of operator-led validation processes to safeguard the integrity of material verification efforts. The first section of this paper details how PG&E’s chemical composition SME review process was used to identify an irregular testing issue that occurred during the analysis of filings samples by a third-party laboratory. PG&E uses multiple NDT methods in tandem, when possible, to enable the cross-checking of data. Since XRF and LIBS were used in addition to filings analysis, the discrepancy was identified through comparison of the data from different sources. Through the SME review process, which involves a careful understanding of the relative performance of various NDT methods in quantifying different elements of interest, it was possible to distinguish real discrepancies from typical data scatter. The result of the error by the third-party testing lab was erroneously high manganese (Mn) measurements, which led to the pipe joint grades being incorrectly calculated as higher than their actual grades. This finding highlights the importance of validating third-party testing labs and carefully examining the data they report; recommended best practices are provided. The second section of this paper demonstrates the impact of NDT errors on the materials verification process by illustrating how errors in measurements of the three elements used for pipe grade calculation (i.e., carbon, sulfur, and manganese) propagate to errors in calculated pipe grade.
Available after the event