1Acuren, Magnolia, Texas, USA. 2WrapMaster Global, Longview, Texas, USA
A full-scale test program was conducted to evaluate the performance of a carbon-epoxy composite repair system for reinforcing crack-like defects in 14-inch × 0.219-inch, Grade X46 LF-ERW (low-frequency electric resistance weld) pipe. Six pipe samples were fabricated from this vintage 1960-era pipe material removed from service. Each sample featured a 3-inch-long axial crack-like defect machined in the ERW seam using electric discharge machining (EDM). Prior to testing, all samples were pre-cycled to initiate cracking at the base of the EDM notches, resulting in final crack depths of approximately 50% of the actual wall thickness.
Of the six test samples, two remained unreinforced to serve as controls, while four were reinforced using the carbon-epoxy system. A fracture mechanics-based design methodology, calibrated against the failure pressure of the unreinforced cracks, was used to determine the optimal composite thickness, calculated to be 0.220 inches.
The repair thickness successfully reinforced one sample through short-term burst testing and another through 25,000 fatigue cycles, simulating approximately 100 years of service under moderate cyclic loading. Encouraged by this performance, the remaining two fatigue samples were subjected to an extended 50,000-cycle runout. One sample completed 43,265 cycles before failure; the other completed the full runout and a subsequent burst test.
This study provides two key contributions to the pipeline industry. First, it validates a fracture mechanics-based design approach for optimizing composite reinforcement. Secondly, it demonstrates that the PermaCarbon carbon-epoxy system offers a minimum design life of 100 years under moderate cyclic conditions.
Available after the event