Accurate Location of Offshore Pipeline Obstructions using Dynamic Pressure Wave Reflection Analysis: Chevron Angola Field Experience

Thursday - January 28 | 16:10 · 5.4 Unpiggable or Difficult-to-Inspect 2

Stuart Mitchell1, Nikolaos Salmatanis2

1PipeSense, Houston, USA, 2Chevron, Houston, USA

AbstractLocating obstructions in offshore pipelines presents a significant operational challenge, particularly when access is limited and conventional methods such as rescue pigs, electromagnetic tracking, or excavation are impractical or costly. Whether caused by stuck pigs, hydrate plugs, debris, or other restrictions, accurately identifying the location of an obstruction is critical to minimizing downtime, reducing operational risk, and planning effective remediation. This paper presents Chevron's operational experience evaluating pressure wave reflection technology to locate pipeline obstructions on two offshore pipelines in Angola. The work demonstrates how induced pressure pulse testing, high-speed pressure acquisition, and dynamic pressure wave reflection analysis can be used to accurately determine the linear location of an obstruction without interrupting normal pipeline operations or requiring specialized tracking tools. The first case study involved a 20-inch natural gas pipeline approximately 35 km in length where only a single field processing unit could be deployed. Because the pipeline was fully obstructed, the speed of sound could not be directly measured and was instead calculated from the pipeline operating conditions and gas composition. Despite these constraints, repeated pressure pulse testing produced consistent reflection signatures that identified the obstruction approximately 11.3 km downstream of the launch facility. The second case study involved a 16-inch offshore crude/multiphase pipeline flooded with seawater. Unlike the first deployment, instrumentation was installed at both ends of the pipeline, allowing the speed of sound to be directly measured from end-to-end pressure wave propagation. Controlled pressure releases from both locations generated repeatable reflection signatures that independently identified the obstruction within approximately 690-733 m of the launcher. The dual-ended configuration improved confidence in the calculated location and demonstrated an obstruction location accuracy of approximately ±30 m under field conditions. Beyond presenting the testing methodology, this paper discusses the practical considerations that influence measurement quality, including sensor placement, release energy, pipeline fluid properties, obstruction proximity to the release location, and the importance of accurately determining wave propagation velocity. Lessons learned from both deployments are compared to illustrate the differences between single-ended and dual-ended testing configurations and the resulting impact on confidence and accuracy. The authors conclude by discussing how dynamic pressure wave reflection analysis provides operators with a rapid, non-intrusive method for locating offshore pipeline obstructions while reducing uncertainty, avoiding unnecessary intervention activities, and improving planning for remediation. The Chevron field experience demonstrates that this approach can provide a practical addition to the pipeline integrity toolkit for locating stuck pigs, hydrate plugs, debris, and other flow restrictions across a wide range of offshore pipeline applications. Keywords - Non-intrusive obstruction detection

Read/Download PaperGradeAvailable after the event