Leak Clamp Qualification Testing

Thursday - January 28 | 16:40 · 8.4 Repair

Parth Patel1, David Futch1, Kimber Burt2, Micah Andrejczak2

1Acuren, Houston, USA, 2Southern Star Central Gas Pipeline, Owensboro, USA

Leak repair solutions are implemented as both temporary measures and permanent repairs. While permanent repair methods such as composite wraps have been extensively validated, temporary fixes such as mechanical leak clamps have undergone comparatively limited testing. These weld-free clamps offer a means of suppressing through-wall leaks on in-service gas and liquid pipelines, providing operators a quick, temporary fix enabling more time to coordinate permanent repairs. However, their performance remains largely uncharacterized across the extensive range of field conditions. This study presents a full-scale test program qualifying a bolted clamp that seats a rubber cone plug over a leak origin, with no welding to the pipe required. Six assemblies were tested across nominal 6-inch and 24-inch diameters under simulated active-leak conditions across three phases: (1) baseline static pressurization to failure, (2) cyclic stability, and (3) failure with a simulated corrosion defect coincident at the leak. This paper explores the findings, examining how clamp performance varies with pipe geometry, pressurization conditions, and defect presence. Collectively, the findings support the use of these clamps as temporary repairs on pipelines operating at reduced pressure.

Read/Download PaperGradeAvailable after the event