Industry Incidents on Natural Gas Transmission Pipelines Resulting from Rupture Failures

Thursday - January 28 | 11:30 · 8.2 Integrity Management 3

Gary Krichau1, David Futch2

1Northern Natural Gas Company, Omaha, USA, 2ADV, Houston, USA

This paper is a review of incident data available from the Pipeline and Hazardous Materials Safety Administration. From 2010 through 2025, there have been 1,984 incidents on natural gas transmission pipelines. Of these incidents, 256 were classified as ruptures. totaling 53,491 feet or 10.1 miles of pipe. These 256 rupture incidents were analyzed by considering the rupture length as a measure of severity. The lengths of the ruptures were compared to the typical pipe attributes such as decade of installation, operating stress, outside diameter, pipe grade, failure root cause, manufacturer, seam type, etc. An unexpected finding was that 189 of these 256 ruptures originated in the pipe body - not the longitudinal seam. This contrasts with what is commonly expected based on research prior to 2010. This paper is intended to bring this to the attention of the industry and ensure that we are not imposing a bias and using current data.

Read/Download PaperGradeAvailable after the event